Heat Shrinkable Terminations Suitable for 3 Core XLPE/EPR Insulated Cables Up to 36kV

CXO/I-1112, CXO/I-1524, CXO/I-3336-SERIES

heat_shrink

Product Description

Compaq Heat Shrinkable Indoor/Outdoor Terminations are designed for 3 Core XLPE / EPR insulated cables Up to 36kV. The design has been focused to provide the basic important functions required for medium voltage power cable accessories including the electric performance, stress relief measure, environmental seal, mechanical fatigues and other related performance parameters laid down in different countries for various service conditions.

Compaq Heat shrink terminations are suitable for indoor (switch gear, cable box, transformer, motor type) and outdoor (pole mounted) terminating of 3 core cable. They are also suitable for 3 Core XLPE/EPR Insulated, Paper Insulated, Lead Covered MIND Cable Up to 36KV.

Features

  • Durability
  • High tensile strength
  • Longer service life
  • Resistance against corrosion
  • Suitable for Mechanical shear head Lugs & Compression Lugs.

SPECIFICATIONS AND STANDARDS:

Meets the requirement of IS: 13573 (2011), IEC 60502, IEEE 48, 404, CENELEC HD 629-1 & other applicable international quality.

Test Description
Requirements
Technical Values
12KV
24KV
36KV
A.C Voltage withstand test (Dry) 5 Minutes at 4.5U ̥ 35kV 58kV 86kV
A.C Voltage withstand test (Wet) 1 Minutes at 4U ̥ (Only Outdoor Termination) 30kV 51kV 76kV
D.C Voltage withstand test 15 Minutes at 4U ̥ 48kV 96kV 144kV
Partial discharge test 10Pc max. at 1.73U ̥ <5Pc Up to 12.7kV <5Pc Up to 25kV <5Pc Up to 33kV
Impulse voltage withstand test 10 impulse each polarity at 75kV 95kV 125kV 170kV
Thermal short circuit (Screen) Two short circuit & no visible deterioration Even confirm to more straight condition
Thermal short circuit (Conductor) Two short circuit & no visible deterioration Even confirm to more straight condition
Dynamic short circuit One short circuit & no visible deterioration Even confirm to more straight condition
Humidity test 300 hours at 1.25 U ̥ Passes
Salt fog test 1000 hours at 1.25 U ̥ Passes

SELECTION GUIDE:


CXO / I 1112 – SERIES

Cable Size(sq. mm)
Kit Code for 12kV
Indoor
Outdoor
16-35 CXI – 11 CXO – 11
50-95 CXI – 12 CXO – 12
120-185 CXI – 13 CXO – 13
240-300 CXI – 14 CXO – 14
400-500 CXI – 15 CXO – 15

CXO / I 1524 – SERIES

Cable Size(sq. mm)
Kit Code for 24kV
Indoor
Outdoor
16-50 CXI – 21 CXO – 21
70-120 CXI – 22 CXO – 22
150-185 CXI – 23 CXO – 23
240-400 CXI – 24 CXO – 24
500 CXI – 25 CXO – 25

CXO / I 3336 – SERIES

Cable Size (sq. mm)
Kit Code for 36kV
Indoor
Outdoor
25-50 CXI – 31 CXO – 31
70-95 CXI – 32 CXO – 32
120-185 CXI – 33 CXO – 33
240-400 CXI – 34 CXO – 34

SIGN-UP FOR UPDATES !