Suitable for 3 Core XLPE/EPR Insulated Cables for 12 kV

CXO/I-1112-SERIES

Heat Shrink Main

Product Description

Heat Shrinkable termination designed for 3 Core XLPE/EPR insulated cables for 12 kV. The design has been focused to provide the basic important functions required for medium voltage power cable accessories including the electric performance, stress relief measure, environmental seal, mechanical fatigues and other related performance parameters laid down in different countries for various service conditions.

Salient Features

  • Simple installation, No special tools required.
  • Excellent performance and reliability.
  • Outstanding dielectric properties.
  • No shelf life limitations upto or below 50oC.
  • Permanent radial pressure equally distributed on cable profiles.
  • Resistance to acids, alkalis, ozone, UV light & fungus.
  • Immediate energizable.
  • Field proven technology.

Technical Specifications

Meets the requirement of IS:13573 (2011), IEC 60502, IEEE 48, 404, CENELEC HD 629-1 & other applicable international quality

Text Discription Requirement GTP value
58kV
A.C Voltage withstand test ( Dry ) 5 minutes at 4.5 U0 51 kV
A.C Voltage Withstand test ( Wet ) 1 minutes at 4.5 U0 96 kV
D.C Voltage Withstand test 15 minutes at 4 U0 48 kV
Partial discharge test 10 Pc Max. at 1.73 U0 <5 Pc upto 25 kV
Impulse Voltage withstand test 10 impulse each polarity at 75KV 125 kV
Thermal Short Circuit ( Screen ) Two short circuit & no visible deterioration Even confirm to more straight condition
Thermal Short Circuit ( Conductor ) Two short circuit & no visible deterioration Even confirm to more straight condition
Dynamic Short Circuit One short circuit & no visible deterioration Even confirm to more straight condition
Humidity Test 300 hours at 1.25 U0 Passes
Salt Fog Test 100 hours at 1.25 U0 Passes

Selection Guide

Cable Size (sq. mm) Kit code
16-50 CXO-21 Enquire Now
70-120 CXO-22 Enquire Now
150-185 CXO-23 Enquire Now
240-400 CXO-24 Enquire Now
500 CXO-25 Enquire Now

Selection Guide

Cable Size (sq. mm) Kit code
16-50 CXO-21 Enquire Now
70-120 CXO-22 Enquire Now
150-185 CXO-23 Enquire Now
240-400 CXO-24 Enquire Now
500 CXO-25 Enquire Now

Meets the requirement of IS:13573 (2011), IEC 60502, IEEE 48, 404, CENELEC HD 629-1 & other applicable international quality

Text Discription Requirement GTP value
58kV
A.C Voltage withstand test ( Dry ) 5 minutes at 4.5 U0 51 kV
A.C Voltage Withstand test ( Wet ) 1 minutes at 4.5 U0 96 kV
D.C Voltage Withstand test 15 minutes at 4 U0 48 kV
Partial discharge test 10 Pc Max. at 1.73 U0 <5 Pc upto 25 kV
Impulse Voltage withstand test 10 impulse each polarity at 75KV 125 kV
Thermal Short Circuit ( Screen ) Two short circuit & no visible deterioration Even confirm to more straight condition
Thermal Short Circuit ( Conductor ) Two short circuit & no visible deterioration Even confirm to more straight condition
Dynamic Short Circuit One short circuit & no visible deterioration Even confirm to more straight condition
Humidity Test 300 hours at 1.25 U0 Passes
Salt Fog Test 100 hours at 1.25 U0 Passes

Selection Guide

Cable Size (sq. mm) Kit code
16-50 CXO-21 Enquire Now
70-120 CXO-22 Enquire Now
150-185 CXO-23 Enquire Now
240-400 CXO-24 Enquire Now
500 CXO-25 Enquire Now

Selection Guide

Cable Size (sq. mm) Kit code
16-50 CXO-21 Enquire Now
70-120 CXO-22 Enquire Now
150-185 CXO-23 Enquire Now
240-400 CXO-24 Enquire Now
500 CXO-25 Enquire Now

SIGN-UP FOR UPDATES !