Cold Shrink 1 & 3 Core Outdoor Termination For XLPE/EPR/PVC/Elastomeric & PILC Cable

CSO - SERIES 11/22/33 kV

Cold Shrink Main (1)

Product Description

6/10 – (12) kV, 6.35/11 – (12) kV, 8.7/15 – (17.5) kV, 12/20 – (24) kV, 12.7/22 – (24) kV, 19/33 – (36) kV

This series of kits are cold shrinkable designed to provide the basic important functions required for medium voltage power cable accessories including the electrical performance, stress relieving needs, environmental seal, mechanical fatigues and other related performance parameters in different countries and various service conditions.

Salient Features

  • Simple installation, No special tools required.
  • Excellent performance and reliability.
  • Outstanding dielectric properties.
  • No shelf life limitations upto or below 50oC.
  • Permanent radial pressure equally distributed on cable profiles.
  • Resistance to acids, alkalis, ozone, UV light & fungus.
  • Immediate energizable.
  • Field proven technology.

Specifications and Standards

Meets the requirement of IS:13573 (2011), IEC 60502, IEEE 48, 404, CENELEC HD 629-1 & other applicable international quality

Text Requirment Requirement Test Value GTP value
12 KV 24 KV 35 KV
A.C Voltage withstand test ( Dry ) 5 minutes at 4.5 U0 35 KV 58 KV 86 KV
A.C Voltage Withstand test ( Wet ) 1 minutes at 4 U0 (only outdoor termination) 30 KV 51 KV 76 KV
D.C Voltage Withstand test 15 minutes at 4 U0 48 KV 98 KV 144 KV
Partial discharge test 10 Pc Max. at 1.73 U0 <5 Pc upto <5 Pc upto <5 Pc upto 12.7 kV 25 kV 33 kV
Impulse Voltage withstand test 10 impulse each polarity at 75KV 95KV 125KV 170KV
Thermal Short Circuit ( Screen ) Two short circuit & no visible deterioration Even confirm to more straight condition
Thermal Short Circuit ( Conductor ) Two short circuit & no visible deterioration Even confirm to more straight condition
Dynamic Short Circuit One short circuit & no visible deterioration Even confirm to more straight condition
Humidity Test 300 hours at 1.25 U0 Passes
Salt Fog Test 1000 hours at 1.25 U0 Passes

Selection Guide

For 12 kV 3 Core Indoor Termination

Cable Size (sq. mm) Kit code
25-50 CCSI-11 Enquire Now
70-120 CCSI-12 Enquire Now
150-240 CCSI-13 Enquire Now
300-400 CCSI-14 Enquire Now

For 24 kV 3 Core Indoor Termination

Cable Size (sq. mm) Kit code
50-95 CCSI-21 Enquire Now
120-185 CCSI-22 Enquire Now
240-400 CCSI-23 Enquire Now

For 36 kV 3 Core Indoor Termination

Cable Size (sq. mm) Kit code
25-70 CCSI-31 Enquire Now
95-185 CCSJ-12 Enquire Now
240-400 CCSJ-13 Enquire Now

For 12 kV 1 Core Indoor Termination

Cable Size (sq. mm) Kit code
25-50 CCSI-11 Enquire Now
70-120 CCSI-12 Enquire Now
150-240 CCSI-13 Enquire Now
300-400 CCSI-43 Enquire Now

For 24 kV 1 Core Indoor Termination

Cable Size (sq. mm) Kit code
50-95 CCSI-21 Enquire Now
120-185 CCSI-22 Enquire Now
240-400 CCSI-23 Enquire Now

For 36 kV 1 Core Indoor Termination

Cable Size (sq. mm) Kit code
50-95 CCSI-21 Enquire Now
120-185 CCSI-12 Enquire Now
240-400 CCSI-13 Enquire Now